JOB CATEGORY
Engineering
EMPLOYMENT TYPE
Full-time
JOB LEVEL
Mid Career
YEARS OF EXPERIENCE
5-6 Years
LANGUAGE
English
Jobseeker Gender
Male
Description
Candidate RESUME
MARUTHAMUTHU SUBBURAJ
Facility Management Professional
Ezdan-38, Al wakra
Doha, Qatar.
Mobile:00974-66499796 Email: [email protected] skype id : [email protected]
Overview
Experienced facility management and maintenance professional with seven years of experiences and versatile engineering skills in the facility operations, especially hard services in the middle east as per the international standards and project requirement.
Specialist-
Power Distribution System – low Voltage and Emergency Low Voltage Switchgear
Uninterruptable power supply Telecommunication
Fire Alarm System Public Address System
Access Control System CCTV
Work ExperienceOver 7 Years of experience in the field of Electrical and Electronics Engineering.
Working as a Sr.Technician (Electrical) from April-2014– Till date in Hamad International Airport, Qatar, (under Contract of FMM Facility Management). Worked as Service Delivery Engineer from July-2010– Jan 2014 in Gemini Communication Ltd, Kerala, India.Worked as Technical Faculty in CADD Centre from Aug2009-Jan2010 in Thiruvallur, Tamilnadu
Academic Qualification
Bachelor of Engineering (Electrical and Electronics Engineering) -2009 passed out-four Year full time regular course
Anna University, Chennai, India (Scored 78%-First Class with Distinction).
FMM/Qatar Airways Hamad International Airport (NDIA) project -Qatar
Period of Employment: April - 2014 to Till Date
Designation: Sr.Technician
FMM is the Facility Management division of World class five stars Qatar Airways New Doha International Airport Project (NDIA). Its new Hamad International Airport is the world’s costliest Airport with All Advanced and latest technologies.
Job Responsibility:
- Direct and Lead the Full Team of Technician for Smooth Operations
- Implement the Preventive and Corrective Maintenance work Schedule as per the International Standard and local Client requirement with very less interruption to Commercial Operation of the Building.
- To Review, monitor, and update the status of the daily Operation and Maintenance activities related to the Facility management.
- Responsible for Corrective measure to be implemented for any sort of Equipment failure and hence avoiding interruption in future.
- briefly explain about the method of Statement and Risk Assessment before starting the work
- Conducting Tool Box talk
- Preparing checklist for Man lift, Lanyard and safety harness, Work at Height
Electrical Switchgear
- Experienced with 11kv Low voltage and 6.6kv Emergency Low voltage Switchgears
- Planned and Implemented Shut down Program of LVSS and ELVSS Switchgear
- Conducted and reviewed Insulation Resistance test for Dry Type Transformer, vacuum Circuit Breaker, Air Circuit Breaker, MCCB, Bus Coupler
- Normally All Airport Normal Loads and Critical Loads are connected to Low Voltage Switchgear via Auto Transfer Switch
- Critical Loads are also connected to Emergency Low Voltage Switchgear which is always OFF Condition
- In case of Emergency the Auto Transfer Switch will send the signal to BMS to Switch ON the ELVSS Generator and transfer the critical Loads to ELVSS.
- Product Handled: - Schneider Electric 6.6kv/415vDry Type Transformer, Vacuum Circuit Breaker, Air Circuit Breaker, Bus Coupler, MCCB, Auto Transfer switch, MCB
Uninterruptable power Supply
- Experienced with double conversion online ups ratings of 10kva, 15kva(manufacture-chloride)
- Handled 5kva, 6kva UPS by Schneider Electric which Provides Double Conversion Power Protection for server, voice and data networks.
- checked Battery voltage using battery Tester
- Prepared preventive maintenance report of charging voltage, temperature, connection resistance and its periodically monitored.
- Quarterly, semi-annual, yearly preventive maintenance activities have been carried out.
Fire Alarm System (FAS) System:
- Edward’s EST3 full advanced Fire Alarm and Detection System from GE with Smoke, Heat, Beam, Duct detectors.
- Trouble shooting, Testing and commissioning and maintenance of fire alarm system at Hamad International airport (HIA).
- HIA airport has connected 60 panels and each panel has 250 devices
- EST3 interfaced with Elevators, Escalators, PA system, Fire smoke damper, ACS.
- SIGA HRS heat detector sensing 15F to 135F
- The response time of Smoke Detector less than 0.5 sec.Tottaly1,60,00 points over 90km of cabling
- Most Familiar with hardware problem identification and Trouble shooting of ground fault, Mapping fault, dirty status of SD
- Good knowledge of Preventive maintenance and Corrective maintenance of FAS are MIMIC panel,FSD,CT2, CT1, SIGA PS, SIGA HS, SIGA HD, SIGA MPS,and other components
- Deep knowledge of Fire Alarm system Edwards EST3 components
- Most familiar with NFPA 72 Codes
- Effectively preparing reports, team control and inspection of the FAS system
- Effective Preventive and Corrective maintenance of Fire alarm System
Access Control System
- Carrying out Preventiveand Corrective Maintenance for ACS doors Which contains door Positioning switch, Sounder, Proximity pin pad Reader, SDC Exit check, panic bar, Lever, Chexit, door holder, door closer, door sensor, Electromagnetic Lock, Interface Connection Box
- Carrying out Preventiveand Corrective Maintenance of Airport Boarding gates, Arrival gates, Passenger Loading Bridge (PLB) Door, Minimum connection Time (MCT) door, Emergency Exit door, Exit stair doors.
- Handling different types of wiring Diagrams i.e. N1, N2, N5, NB1, A1, C1, C2, S, CD1-0, CB2.
- Carrying out Preventiveand Corrective Maintenance of Safe-O-Tronic RFID Lockers.
- Carrying out Preventiveand Corrective Maintenance of Barriers- intelligate.
- Products Handled: SDC 101 DE Exit check, SDC 1561 Micro Shear EMLOCKS, Von Duprin CX 33A chexit device, PS 914 Power Supply cum Battery Charging Kit, AL600ULB Power supply and charger. Lenel ICB, Von Duprin ICB.
Project Details in Gemini Communication Ltd., July-2010 – January 2014
Period of Employment: July - 2010 to January 2014
Designation: Service Delivery Engineer (Telecommunication)
1. Project Name: RF Survey
Telecom operator:-Tata Communication Ltd
Project Overview: Planned and Implemented the RF Survey by using radwin 2000 Modem. Purpose of this survey is checking the interference around BTS for TX (dbm) power in different Unlicensed Frequencies from 5.830 GHz to 5.875 GHz at 30m Height from Ground. So that placing sectors with specified frequency can be determined.
Products Handled: Radwin Wireless Modem (2000 series), Motorola (Canopy).
2. Project Name: Wimax BTS Implementation
Telecom operator:-Tata Communication Ltd
Project Overview: Planned and Implemented Wimax BTS and Commissioned several sites across Kerala. In this Project my job role is checking the Antenna Tilt, Height, and Degree. Calculated the cable loss and return loss by using vswr meter. IF cable is used between ODU to IDU.
Products Handled: Telsima StarMaxODU and StarMAX6102IDU, MROTEK RICI-4E1L & PINE 8E1/FE/AC/DC, VSWR,Frequencies-3.3Ghz to 3.7 GHz. Aperto ODU and IDU, Motorola (Canopy) ODU and IDU,Frequencies 5.830GHz to 5.875 GHz.
3. Project Name: Wimax Wireless Data Connectivity
Telecom operator:-Tata Communication Ltd
Project Overview: Planned and Implemented the Corporate Intranet Connectivity for VPN and Lease Line Customers via Wireless Data Connectivity. Telsima ODU, Licensed Frequency 3.3GHz to 3.7 GHz used for getting Signal from Nearest Base Stations. Downlink qam64-3/4 and uplink qam64-1/2 Modulation Techniques used. In Aperto & Motorola modems 5.830Ghz to5.875Ghz Unlicensed Frequency used. Downlink qam64-3/4 and uplink qam64-1/2 Modulation Techniques used for Getting Signal.
Products Handled: Telsima StarMax ODU and POE, Aperto Networks ODU and POE, Cat5e Cable, Motorola (Canopy) ODU and POE.
4. Project Name: Point to Point Wireless Data Connectivity
Telecom operator:-Tata Communication Ltd
Project Duration- (June 2013-Jan 2014)
Project Overview: Planned and Implemented the Corporate Intranet Connectivity for VPN and Lease Line Customers via Wireless Data Connectivity
Products Handled: Radwin Win link 2.4 GHz and 5.8 GHz Wireless Modems, Radwin Manager Software, POE, MROTEK RICI-E1, MROTEK PINE 8E1/FE/AC/DC Converters.Cat5e Cable.
Personal DetailsName : Maruthamuthu.S
Date of Birth : May 27-1988
Sex : Male
Marital Status : Single
Nationality : Indian
Passport No : H7447638
Languages Known : English, Tamil, Malayalam, and Hindi.
Place : Signature
Date : (S.Maruthamuthu)
Information